The European Biological Variation Study (EuBIVAS): weekly biological variation of cardiac troponin I estimated by the use of two different high-sensitivity cardiac troponin I assays

  • Ferruccio Ceriotti ORCID logo EMAIL logo , Jorge Díaz-Garzón Marco , Pilar Fernández-Calle , Alessio Maregnani , Aasne K. Aarsand , Abdurrahman Coskun , Niels Jonker , Sverre Sandberg , Anna Carobene and on behalf of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group on Biological Variation

Abstract

Background

Cardiac troponins (cTn) are specific markers for cardiac damage and acute coronary syndromes. The availability of new high-sensitivity assays allows cTn detection in healthy people, thus permitting the estimation of biological variation (BV) of cTn. The knowledge of BV is important to define analytical performance specifications (APS) and reference change values (RCVs). The aim of this study was to estimate the within- and between-subject weekly BV (CVI, CVG) of cTnI applying two high-sensitivity cTnI assays, using European Biological Variation Study (EuBIVAS) specimens.

Methods

Thirty-eight men and 53 women underwent weekly fasting blood drawings for 10 consecutive weeks. Duplicate measurements were performed with Singulex Clarity (Singulex, USA) and Siemens Atellica (Siemens Healthineers, Germany).

Results

cTnI was measurable in 99.4% and 74.3% of the samples with Singulex and Atellica assays, respectively. Concentrations were significantly higher in men than in women with both methods. The CVI estimates with 95% confidence interval (CI) were for Singulex 16.6% (15.6–17.7) and for Atellica 13.8% (12.7–15.0), with the observed difference likely being caused by the different number of measurable samples. No significant CVI differences were observed between men and women. The CVG estimates for women were 40.3% and 36.3%, and for men 65.3% and 36.5% for Singulex and Atellica, respectively. The resulting APS and RCVs were similar for the two methods.

Conclusions

This is the first study able to estimate cTnI BV for such a large cohort of well-characterized healthy individuals deriving objective APS and RCV values for detecting significant variations in cTnI serial measurements, even within the 99th percentile.

Introduction

Cardiac troponin (cTn) assays are the mainstay for the diagnosis of acute myocardial infarction (AMI) [1], [2], [3] as well as markers of cardiac damage [4], [5] and prognostic indicators of all-cause mortality [6]. It is critical to understand if the observed variations in cTn concentration are really associated with a pathological condition or may just be attributable to analytical and biological variation (BV). The availability of new high-sensitive [7] or even “ultra-sensitive” [8], [9] methods allows for measurement of cTnI in the majority of healthy subjects, allowing for the use of cTn as a risk indicator in the general population, for which there is increasing evidence [4], [6], [10]. This enhances the need for relevant and robust estimates of BV also in a long-term setting in healthy individuals to aid in the interpretation of changes in cTn, as well as establishing reference change value (RCV) and analytical performance specifications (APS) for the use of cTn in such a manner [11]. Currently available BV data for cTnI BV have been summarized by Nordenskjöld et al. [12] and are mostly based on [1] analysis with a non-commercial analytical system [13]], [[2] small cohorts of potentially unhealthy individuals [12], [14], [15] or [3] based on sampling with a short time interval (24 h) [16]. The scope of our study was to estimate the weekly BV of high-sensitive cTnI with two recently released commercial methods targeting different epitopes, Siemens Atellica and Singulex Clarity (Singulex is as of June 2019 no longer on the market), on the well-characterized population of the European Biological Variation Study (EuBIVAS) [17], [18], [19], [20]. The study has been conducted in accordance with the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) recommendations [21].

Materials and methods

Individuals

Ninety-one volunteers from five European countries (Italy, Spain, The Netherlands, Norway and Turkey) participated in the EuBIVAS. Their characteristics are reported in Supplementary Tables 1 and 2, and their health status and the exclusion criteria applied are described elsewhere in detail [17]. Briefly, 38 men (22–59 years) and 53 women (21–69 years), all Caucasians, underwent weekly fasting blood drawings for 10 consecutive weeks (April–June 2015). All the centers followed the same preanalytical protocol and used the same blood drawing devices and collection tubes (Becton Dickinson, NJ, USA). Serum and EDTA plasma samples were aliquoted and sent, frozen in dry ice, to the coordinating center San Raffaele Hospital in Milan and stored in a freezer at −80°C until distribution to Clinical laboratory of Policlinico of Milan, Italy (EDTA plasma) and to the Department of Laboratory Medicine Hospital Universitario La Paz Madrid, Spain (serum) for the cTnI analysis (April–July 2018).

The EuBIVAS protocol was approved by the Institutional Ethical Review board of San Raffaele Hospital in agreement with the World Medical Association Declaration of Helsinki and by the Ethical Board/Regional Ethics Committee for each center. All participants signed a written consent form.

cTnI analysis

Two different analytical systems were applied, with analysis being performed in two different centers.

Center 1. Policlinico of Milan. The analyses were performed on the Sgx Clarity System (Singulex, Alameda, CA, USA), using EDTA plasma as sample material. All samples were measured in duplicate, with all samples obtained from the same subject being measured using a single reagent pack in a single analytical run. The same single reagent lot was used for analysis of samples from all subjects. Due to the analytical throughput of the analyzer, a maximum of eight subjects per day were measured (160 measurements/day). Sgx Clarity cTnI Controls (Singulex, Alameda, CA, USA) were used as quality control materials.

Center 2. Hospital Universitario La Paz Madrid. The analyses were performed on Siemens Atellica (Siemens Healthineers, Erlangen, Germany), using serum as sample material. All samples were measured in duplicate. All samples obtained from the same subject were measured using a single reagent pack in a single analytical run. All samples were measured for 3 consecutive days (30 subjects, 600 measurements/day) with the same reagent lot. Liquichek Cardiac Markers Plus (Bio-Rad, Hercules, CA, USA) was used as quality control material.

The technical characteristics of the two analytical methods are provided in Supplementary Table 3.

Data analysis

Calculation of the within-subject BV (CVI) estimates was performed using CV-ANOVA, an ANOVA method where data first are transformed using the CV transformation [22]. The CV-ANOVA was adopted for the analysis as this straightforward, non-parametric procedure has been shown to be a robust, largely distribution-free procedure for estimating CVA and CVI in three-level nested random models [22]. Outlier identification and removal were performed for replicates and samples on the CV-transformed data, by assessing homogeneity of analytical CV (CVA) (between-replicates) using the Bartlett test [23] and homogeneity of CVI using the Cochran test [24]. To evaluate differences in concentrations between participants from the different countries, data were visually inspected (data not shown). To examine if there was a general trend in the overall concentration over the study period, as described for other measurands in the EuBIVAS [19], and if individuals were at steady state, we calculated the regression of the mean of the 180 duplicate analysis from every blood drawing 1, 2 …. 10 (pooled mean group sample concentrations) versus the blood drawing number [1], [2], [3], [4], [5], [6], [7], [8], [9], [10]. Subjects were considered in steady state if the 95% confidence intervals (CI) of the slope of the regression line included zero. Larger individual systematic changes were identified by the homogeneity test of the CVI (Cochran test). The between-subject BV (CVG) was estimated by ANOVA on natural log-transformed data after applying the Dixon Q test to detect outliers between individuals and the Shapiro-Wilk test to verify the normality assumption [25].

APS for the analytical imprecision (CVAPS), analytical bias (BAPS), RCV and the number of samples needed to reach the homeostatic set point were calculated according to the formulas reported in the Supplementary Appendix.

Data analyses were performed using Excel 2010 and IBM SPSS statistics, version 23.

Results

The Atellica assay has a higher limit of detection (LoD) than Singulex (Supplementary Table 3), with consequences for the number of subjects with measurable cTnI concentrations. With the Singulex method, just one subject out of 91 had one sample<LoD in both replicates; in total 99.4% of samples had measurable concentrations (non-reportable results 10 out of 1781 analyses). With the Atellica method, only 1286 results out of 1731 measurements (74.3%) were higher than the LoD. So, for the Atellica method, six individuals had no measurable values and another 17 had <5 measurable samples. All these 23 with non-measurable cTnI were excluded from the calculation, 21 of whom were women.

About 6% of the data for each of the two methods were eliminated as outliers prior to calculation of CVI estimates (see Supplementary Table 4 for details). The eliminated samples were the same for both methods, except for a few samples due to the different LoD. Only two individuals (one man and one woman) had samples with concentrations higher than the 99th percentile for both methods. The woman (24 years) had cTnI concentrations >99th percentile in the last two collected samples when cTnI was measured with the Singulex assay. Using the Atellica assay, seven out of her 10 samples were above the 99th percentile for women of 38.6 ng/L, varying from 40 to 114 ng/L. The man presented a cTnI peak in one sample (1380 ng/L for Singulex and 7000 ng/L for Atellica) and four other samples just above the 99th percentile for men with both methods. This study subject was an athlete doing weightlifting and the peak sample was taken after strenuous training exercise; the creatine kinase in the same sample gave a result of 18,500 U/L. Both subjects were excluded from the calculations. All the other subjects included in the calculation were in steady state. Different numbers of individuals were eliminated as outliers based on the Dixon test for the two methods prior to the calculation of CVG: one woman for Singulex and two women and four men for Atellica (see Figures 1 and 2 and Supplementary Table 4). The results of CVA, CVI and CVG estimates obtained for both methods are reported in Table 1. When including different number of study subjects as basis for the CVI estimates due to the higher LoD for Atellica, the CVI estimates obtained with the Singulex Clarity and Atellica systems were significantly different (i.e. the 95% CI did not overlap) only for the whole study population (upper part of Table 1). Results for the male subgroups were similar, for the female subgroup slightly different, but with overlapping 95% CI. If, however, only including the Singulex results from the study subjects who were used as basis for the Atellica estimates, the Singulex CVI estimates decreased and, even if Atellica estimates remained lower, results were no longer statistically different (overlapping 95% CI for all subgroups, see Table 1). Mean cTnI values were highly different between the two methods, on average about 3 times higher for the Atellica system (Table 1). The calculated APS and RCVs were similar for the two methods, as was the case also for the index of individuality (II) and the number of samples needed to reach the homeostatic set point (±10%) (Table 2). Only for men measured on Singulex was the II much lower as a consequence of the higher CVG.

Figure 1: 
cTnI Singulex Clarity.
Range minimum to maximum and median value (hyphen) for each individual ordered by age. The gray bar indicates the median±CI; continuous lines indicate the 5th and 95th percentiles for women and men. The figures report all the individuals whose samples were included to derive CVI estimates, and those not included in the calculation of CVG are circled.
Figure 1:

cTnI Singulex Clarity.

Range minimum to maximum and median value (hyphen) for each individual ordered by age. The gray bar indicates the median±CI; continuous lines indicate the 5th and 95th percentiles for women and men. The figures report all the individuals whose samples were included to derive CVI estimates, and those not included in the calculation of CVG are circled.

Figure 2: 
cTnI Siemens Atellica.
Range minimum to maximum and median value (hyphen) for each individual ordered by age. The gray bar indicates the median±CI; continuous lines indicate the 5th and 95th percentiles for women and men. The figures report all the individuals whose samples were included to derive CVI estimates, and those not included in the calculation of CVG are circled.
Figure 2:

cTnI Siemens Atellica.

Range minimum to maximum and median value (hyphen) for each individual ordered by age. The gray bar indicates the median±CI; continuous lines indicate the 5th and 95th percentiles for women and men. The figures report all the individuals whose samples were included to derive CVI estimates, and those not included in the calculation of CVG are circled.

Table 1:

Within-subject (CVI) and between-subject (CVG) biological variation (BV) estimates for cTnI with 95% CIs.

Number of individuals Total number of results Mean number of samples/individual Mean number of replicates/sample Mean value, ng/L (95% CI)a CVA% (95% CI)b CVI% (95% CI) CVG% (95% CI)
cTnI Singulex Clarity all subjects
 All data 89 1667 9.43 1.97 0.78 (0.75–0.82) 11.6 (11.1–12.2) 16.6 (15.6–17.7)
 Men 37 682 9.22 2.00 1.06 (1.00–1.13) 15.0 (13.7–16.6) 65.3 (51.1–90.0)
 Women <50 years 42 786 9.48 1.98 0.47 (0.44–0.50) 17.8 (16.0–19.5) 40.3 (33.5–55.0)
 Women >50 years 10 199 10 1.99 0.91 (0.86–0.99) 16.7 (14.3–19.9) 36.8 (24.5–73.0)
cTnI Singulex Clarity same subjects as Siemens Atellica
 All data 66 1240 9.42 1.99 0.92 (0.88–0.97) 10.8 (10.3–11.5) 15.8 (14.7–17.0)
 Men 35 644 9.20 2.00 1.10 (1.04–1.17) 15.8 (14.4–17.4) 59.5 (46.5–81.7)
 Women <50 years 23 437 9.57 1.97 0.62 (0.58–0.66) 17.1 (14.8–19.5) 42.3 (31.6–63.4)
 Women >50 years 8 159 10 1.98 1.00 (0.94–1.06) 16.1 (13.4–19.6) 30.9 (19.7–68.3)
cTnI Siemens Atellica
 All data 66 1135 9.00 1.84 2.85 (2.78–2.92) 10.7 (10.1–11.4) 13.9 (12.715.0)
 Men 35 602 8.94 1.92 3.06 (2.96–3.16) 14.7 (13.1–16.3) 36.5 (29.7–52.4)
 Women <50 years 23 386 8.91 1.79 2.76 (2.59–2.94) 14.6 (12.5–16.7) 36.3 (26.9–54.2)
 Women >50 years 8 149 9.63 1.94 2.93 (2.79–3.08) 12.8 (9.7–16.2) 28.8 (19.8–68.7)
  1. aAfter elimination of outliers. bAnalytical variation (CVA) estimates were based on CV-ANOVA of duplicate analysis of all study samples. The numbers in bold are those used for the calculation of APS reported in Table 2.

Table 2:

Analytical performance specification (APS) for imprecision (CVAPS) and bias (BAPS), reference change values (RCVs), index of individuality and number (No.) of samples needed to reach the homeostatic set point based on the biological variation estimates as reported in Table 1.

CVAPS (%)a BAPS (%)b RCV (%)cdecrease; increase Index of individuality No. of samples needed to reach the homeostatic set point ±10%
Singulex Clarity 8.3 10.9 −37.4/59.7 Men 0.23

Women 0.44
Men 14

Women 17
Siemens Atellica 6.9 9.7 −33.4/50.1 Men 0.40

Women 0.40
Men 13

Women 13
  1. aCVAPS=½ CVI; b B A P S = 0 . 2 5 ( C V I 2 + C V G 2 ) 0 . 5 ; cRCVs were calculated as described in the text delivering asymmetric values for rise and fall at the probability level of 95% for significant unidirectional change, applying CVA estimates based on duplicate measurement of all study samples.

Discussion

The availability of high-sensitivity cTnI methods with a very low LoD and good precision at low cTnI concentrations allows the delivery of CVI estimates in healthy individuals. This is important because it allows the definition of APS based on BV and the definition of RCV based on biology. The CVA estimates derived from duplicate analysis of the study samples are higher than the calculated CVAPS but it must be taken into consideration that this CVA estimate is obtained at a mean cTnI concentration <1 ng/L and <3 ng/L for Singulex Clarity and Siemens Atellica, respectively, concentrations which are about 10 times lower than the respective 99th percentile of the healthy population (see Supplementary Table 3). Although significant differences were observed between CVI estimates based on the two analytical systems for the overall group and the female subgroup, this is likely explained by the different level of sensitivity of the two analytical methods and not by the different epitopes that they recognize. Both systems can be categorized as highly sensitive methods [3], [26], but for Atellica, in line with the manufacturer’s specifications, about 75% of the samples were above the LoD and 25% were below (not measurable), while for Singulex more than 99% were measurable. The individuals with non-measurable samples were mostly women (21 out 53, 40% of females’ results) and only two were men (5.4% of the 37 males’ results). Thus, the female study population is substantially different for the two methods and this explains the different CVI estimates observed between women and consequently for the overall estimate. In line with this, when the estimates were based on results from the same study subjects (second part of Table 1), the Singulex estimates decreased, and the difference was no longer significantly different. Another possible contributor to the differences in estimates is the sample materials on which the analyses were performed: serum for Atellica and EDTA plasma for Singulex.

Our data confirm that women present with lower cTnI values, as has been reinforced in several recent papers [27], [28], [29]. The difference between men and women is more evident for Singulex, but as previously detailed, for Atellica 40% of the women had cTnI concentrations below the LoD and were thus not included in the calculations. It is important to notice the relevant difference in standardization of the two analytical methods: Siemens Atellica results were on average 3 times greater than Singulex Clarity results but for some subjects (seven out of the included 66, five women and two men) the difference was more than 10 times. This behavior was constant across all the 10 samples of these particular subjects, indicating a difference in the way the two systems detect and quantify the cTnI molecule for these specific subjects. The Singulex Clarity cTnI assay uses a 2×2 pair of monoclonal antibodies recognizing epitopes in the central region and at both ends of the cTnI molecule; the capture antibodies recognize the amino acid sequences 41–49 and 24–40 and the detection antibodies recognize the sequences 190–196 and 86–90. Siemens Atellica uses two capture monoclonal antibodies that recognize epitopes in the C- and N-terminal part of the cTnI molecule and a third detection antibody recognizes the N-terminal region of the molecule. This different setting of the Atellica method that has the capture antibodies at the extreme of the cTnI molecule (while Singulex captures the central more stable part of the molecule) could be more sensitive to intact cTnI deriving from recent myocardial damage possibly present in subjects with higher cTnI values [30], [31].

These EuBIVAS-derived CVI estimates are in line with those published by Wu et al. [13] where a research version of the Singulex analytical system was applied and by Simpson et al. [32], but higher than estimates based on short-term sampling intervals (within 24 h) [16].

For all but two subjects, all cTnI results were well within the 99th percentile for both methods, including those subjects who were excluded from the CVG calculations.

The CVG estimates obtained with the Atellica system (36.5% and 36.3% for men and women, respectively) as well as the Singulex CVG for the female group (40.3%) were lower than the previously published data. The Singulex CVG estimate for men (65.3%) was in line with those published by Vasile et al. [33], Wu et al. [13] and van der Linden et al. [16] but lower than some other published data. For the Singulex method, the only excluded subject from CVG calculation was a 47-year-old lady practicing about 17 h per week with strenuous physical exercise (running and cycling) [30]. This subject was an outlier also for Atellica. As evident in Figures 1 and 2, her cTnI results were in the range of the male subjects. The lower Atellica-derived CVG estimate for men is likely explained by the exclusion of study subjects classified as outliers, who were not excluded for Singulex. In fact, with the Atellica method, four subjects had significantly higher concentrations than the others (see Figure 2) and were excluded according to the Dixon algorithm for outlier detection. The same subjects had higher cTnI concentrations when measured by the Singulex method than the rest of the group, but not to such a high level that they were classified as outliers. This may be explained by the different epitope mappings of the two analytical systems.

The distribution of the homeostatic points of cTnI of the individuals is skewed, and this is reflected by the high CVG values (>33%) (Table 1), indicating the need to be cautious when applying such estimates for further calculations, especially APS for bias.

The low II reduces the relevance of reference intervals and increases the importance of applying RCV when interpreting serial results. The EuBIVAS-derived asymmetrical RCVs were similar for the two analytical systems: about 35% for decrease and between 50% and 60% for increase. These RCVs are thus quite similar to those summarized by Nordenskjöld et al. [12] and Simpson et al. [32] and confirm the amount of variation expected to be caused by analytical variation and BV when monitoring a patient with cTnI within the 99th percentile. Recently, cTnI has been proposed as a prognostic marker and its rapid increase (within the 99th percentile) may indicate an accelerated myocardial damage [10], so knowledge on the natural BV in the long-term setting is of importance. Furthermore, in patients undergoing therapies with potentially cardiotoxic drugs, the obtained data would be highly relevant. Unfortunately, at these low concentration levels, 13–17 samples are needed to identify the homeostatic set point ±10%, while 3–4 samples are sufficient to estimate the set point within ±20%.

The limitations of the study are as follows: long sample storage before analysis (3 years), but the samples were continuously stored at −80°C and thawed only prior to analysis; the study was not targeted to cTn so participants did not undergo specific cardiological evaluation and there is, in particular, a low prevalence of male elderly subjects. Furthermore, this study establishes BV estimates based on weekly sampling and the obtained results thus cannot be directly applied to AMI diagnosis and would therefore also not be appropriate to establish APS in an emergency context.

Conclusions

This is the first study able to estimate CVI and CVG based on weekly samplings applying two different recently available high-sensitivity cTnI methods on a large cohort of well-characterized healthy individuals, thus delivering APS and RCV allowing for objectively defined quality requirements for analytical methods and for detecting likely significant variations when performing serial measurements of cTnI within the 99th percentile.


Corresponding author: Ferruccio Ceriotti, Clinical Laboratory, Fondazione IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Via Francesco Sforza 28, 20122 Milan, Italy, Phone: +390255032876, Fax: +390255032219

Acknowledgments

We thank Singulex that allowed us to work on a dedicated Singulex Clarity and donated us all the necessary reagents and Siemens that donated the reagents for the Atellica analyses. We would also like to thank all study participants and other EuBIVAS partners for their contribution: Gerhard Barla, Bill Bartlett, Giulia Cajano, Mario Plebani, Thomas Røraas, Una Ørvim Sølvik, Marit Sverresdotter Sylte, Mustafa Serteser, Francesca Tosato and Ibrahim Unsal.

  1. Author contributions: All the authors have accepted responsibility for the entire content of this submitted manuscript and approved submission.

  2. Research funding: None declared.

  3. Employment or leadership: None declared.

  4. Honorarium: None declared.

  5. Competing interests: The funding organization(s) played no role in the study design; in the collection, analysis, and interpretation of data; in the writing of the report; or in the decision to submit the report for publication.

References

1. Thygesen K, Alpert JS, Jaffe AS, Chaitman BR, Bax JJ, Morrow DA, et al. Fourth universal definition of myocardial infarction (2018). J Am Coll Cardiol 2018;72:2231–64.10.1016/j.jacc.2018.08.1038Search in Google Scholar PubMed

2. Roffi M, Patrono C, Collet J-P, Mueller C, Valgimigli M, Andreotti F, et al. 2015 ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation. Eur Heart J 2016;37:267–315.10.1093/eurheartj/ehv320Search in Google Scholar PubMed

3. Wu AH, Christenson RH, Greene DN, Jaffe AS, Kavsak PA, Ordonez-Llanos J, et al. Clinical Laboratory Practice Recommendations for the Use of Cardiac Troponin in Acute Coronary Syndrome: Expert Opinion From the Academy of the American Association for Clinical Chemistry and the Task Force on Clinical Applications of Cardiac Bio-Markers of the International Federation of Clinical Chemistry and Laboratory Medicine. Clin Chem 2018;64:645–55.10.1373/clinchem.2017.277186Search in Google Scholar PubMed

4. Blankenberg S, Salomaa V, Makarova N, Ojeda F, Wild P, Lackner KJ, et al. Troponin I and cardiovascular risk prediction in the general population: the BiomarCaRE consortium. Eur Heart J 2016;37:2428–37.10.1093/eurheartj/ehw172Search in Google Scholar PubMed PubMed Central

5. Body R, Carlton E. Understanding cardiac troponin part 1: avoiding troponinitis. Emerg Med J 2018;35:120–5.10.1136/emermed-2017-206812Search in Google Scholar PubMed

6. Fan Y, Jiang M, Gong D, Man C, Chen Y. Cardiac troponin for predicting all-cause mortality in patients with acute ischemic stroke: a meta-analysis. Biosci Rep 2018;38:BSR20171178.10.1042/BSR20171178Search in Google Scholar PubMed PubMed Central

7. Apple FS, Collinson PO. Analytical characteristics of high-sensitivity cardiac troponin assays. Clin Chem 2012;58:54–61.10.1373/clinchem.2011.165795Search in Google Scholar PubMed

8. Todd J, Freese B, Lu A, Held D, Morey J, Livingston R, et al. Ultrasensitive flow-based immunoassays using single-molecule counting. Clin Chem 2007;53:1990–5.10.1373/clinchem.2007.091181Search in Google Scholar PubMed

9. Garcia-Osuna A, Gaze D, Grau-Agramunt M, Morris T, Telha C, Bartolome A, et al. Ultrasensitive quantification of cardiac troponin I by a Single Molecule Counting method: analytical validation and biological features. Clin Chim Acta 2018;486:224–31.10.1016/j.cca.2018.08.015Search in Google Scholar PubMed

10. Lyngbakken MN, Røsjø H, Holmen OL, Dalen H, Hveem K, Omland T. Temporal changes in cardiac troponin I are associated with risk of cardiovascular events in the general population: the Nord-Trøndelag Health Study. Clin Chem 2019;65:871–81.10.1373/clinchem.2018.301069Search in Google Scholar PubMed

11. Fraser CG, Harris EK. Generation and application of data on biological variation in clinical chemistry. Crit Rev Clin Lab Sci 1989;27:409–37.10.3109/10408368909106595Search in Google Scholar PubMed

12. Nordenskjöld AM, Ahlstrom H, Eggers KM, Frobert O, Jaffe AS, Venge P, et al. Short- and long-term individual variation in cardiac troponin in patients with stable coronary artery disease. Clin Chem 2013;59:401–9.10.1373/clinchem.2012.191700Search in Google Scholar PubMed

13. Wu AH, Quynh AL, Todd J, Moecks J, Wians F. Short- and long-term biological variation in cardiac troponin I measured with a high-sensitivity assay: Implications for clinical practice. Clin Chem 2009;55:52–8.10.1373/clinchem.2008.107391Search in Google Scholar PubMed

14. Scharnhorst V, Krasznai K, van’ t Veer M, Michels RH. Variation of cardiac troponin I and T measured with sensitive assays in emergency department patients with noncardiac chest pain. Clin Chem 2012;58:1208–14.10.1373/clinchem.2011.179903Search in Google Scholar PubMed

15. Wu AH, Akhigbe P, Wians F. Long-term biological variation in cardiac troponin I. Clin Biochem 2012;45:714–6.10.1016/j.clinbiochem.2012.03.008Search in Google Scholar PubMed

16. van der Linden N, Hilderink JM, Cornelis T, Kimenai DM, Klinkenberg LJ, van Doorn WP, et al. Twenty-four-hour biological variation profiles of cardiac troponin I in individuals with or without chronic kidney disease. Clin Chem 2017;63:1655–6.10.1373/clinchem.2017.275107Search in Google Scholar PubMed

17. Carobene A, Strollo M, Jonker N, Barla G, Bartlett WA, Sandberg S, et al. Sample collections from healthy volunteers for biological variation estimates’ update: a new project undertaken by the Working Group on Biological Variation established by the European Federation of Clinical Chemistry and Laboratory Medicine. Clin Chem Lab Med 2016;54:1599–608.10.1515/cclm-2016-0035Search in Google Scholar PubMed

18. Carobene A, Røraas T, Sølvik UØ, Sylte MS, Sandberg S, Guerra E, et al. Biological variation estimates obtained from 91 healthy study participants for 9 enzymes in serum. Clin Chem 2017;63:1141–50.10.1373/clinchem.2016.269811Search in Google Scholar PubMed

19. Aarsand AK, Díaz-Garzón J, Fernandez-Calle P, Guerra E, Locatelli M, Bartlett WA, et al. The EuBIVAS: within- and between-subject biological variation data for electrolytes, lipids, urea, uric acid, total protein, total bilirubin, direct bilirubin, and glucose. Clin Chem 2018;64:1380–93.10.1373/clinchem.2018.288415Search in Google Scholar PubMed

20. Carobene A, Aarsand AK, Guerra E, Bartlett WA, Coşkun A, Díaz-Garzón J, et al. European Biological Variation Study (EuBIVAS): within- and between-subject biological variation data for 15 frequently measured proteins. Clin Chem 2019;65:1031–41.10.1373/clinchem.2019.304618Search in Google Scholar PubMed

21. Bartlett WA, Braga F, Carobene A, Coşkun A, Prusa R, Fernandez-Calle P, et al. A checklist for critical appraisal of studies of biological variation. Clin Chem Lab Med 2015;53:879–85.10.1515/cclm-2014-1127Search in Google Scholar PubMed

22. Røraas T, Støve B, Petersen PH, Sandberg S. Biological variation: the effect of different distributions on estimated within-person variation and reference change values. Clin Chem 2016;62:725–36.10.1373/clinchem.2015.252296Search in Google Scholar PubMed

23. Snedecor GW, Cochran WG. Statistical methods, 8th ed. Iowa City, IA, USA: Iowa State University Press, 1989.Search in Google Scholar

24. Cochran W. The distribution of the largest of a set of estimated variances as a fraction of their total. Ann Eugen 1941;11:47–52.10.1111/j.1469-1809.1941.tb02271.xSearch in Google Scholar

25. Shapiro S, Wilk M. An analysis of variance test for normality (complete samples). Biometrika 1965;52:591.10.1093/biomet/52.3-4.591Search in Google Scholar

26. Apple FS. A new season for cardiac troponin assays: it’s time to keep a scorecard. Clin Chem 2009;55:1303–6.10.1373/clinchem.2009.128363Search in Google Scholar PubMed

27. Kimenai DM, Janssen EB, Eggers KM, Lindahl B, den Ruijter HM, Bekers O, et al. Sex-specific versus overall clinical decision limits for cardiac troponin I and T for the diagnosis of acute myocardial infarction: a systematic review. Clin Chem 2018;64:1034–43.10.1373/clinchem.2018.286781Search in Google Scholar PubMed

28. Clerico A, Ripoli A, Masotti S, Musetti V, Aloe R, Dipalo M, et al. Evaluation of 99th percentile and reference change values of a high-sensitivity cTnI method: a multicenter study. Clin Chim Acta 2019;493:156–61.10.1016/j.cca.2019.02.029Search in Google Scholar PubMed

29. Clerico A, Masotti S, Musetti V, Ripoli A, Aloe R, Di Pietro M, et al. Evaluation of 99th percentile and reference change values of the hs-cTnI method using ADVIA Centaur XPT platform: A multicenter study. Clin Chim Acta 2019;495:161–6.10.1016/j.cca.2019.04.056Search in Google Scholar PubMed

30. Gresslien T, Agewall S. Troponin and exercise. Int J Cardiol 2016;221:609–21.10.1016/j.ijcard.2016.06.243Search in Google Scholar PubMed

31. deFilippi C, Seliger S, Latta F, Peters M, Christenson R, Dickfeld T, et al. High-sensitivity cardiac troponin assays potentially differentiate acute from chronic myocardial injury. J Am Coll Cardiol 2019;73:2904–5.10.1016/j.jacc.2019.03.487Search in Google Scholar PubMed

32. Simpson AJ, Potter JM, Koerbin G, Oakman C, Cullen L, Wilkes GJ, et al. Use of observed within-person variation of cardiac troponin in emergency department patients for determination of biological variation and percentage and absolute reference change values. Clin Chem 2014;60:848–54.10.1373/clinchem.2013.219410Search in Google Scholar PubMed

33. Vasile VC, Saenger AK, Kroning JM, Klee GG, Jaffe AS. Biologic variation of a novel cardiac troponin I assay. Clin Chem 2011;57:1080–1.10.1373/clinchem.2011.162545Search in Google Scholar PubMed


Supplementary Material

The online version of this article offers supplementary material (https://doi.org/10.1515/cclm-2019-1182).


Received: 2019-11-16
Accepted: 2020-03-10
Published Online: 2020-04-17
Published in Print: 2020-09-25

©2020 Walter de Gruyter GmbH, Berlin/Boston